Mass Spectrometry - PowerPoint PPT Presentation

About This Presentation
Title:

Mass Spectrometry

Description:

Mass Spectrometry. Mass spectrometry involves ionizing a compound, ... RH S RSH (R = reagent, S = sample, e = electron, . = radical electron , H = hydrogen) ... – PowerPoint PPT presentation

Number of Views:924
Avg rating:3.0/5.0
Slides: 20
Provided by: wsu6
Category:
Tags: mass | rsh | spectrometry

less

Transcript and Presenter's Notes

Title: Mass Spectrometry


1
Mass Spectrometry
Mass spectrometry involves ionizing a compound,
separating the ions that result on the basis of
mass to charge ratio (m/z) and obtaining a plot
of number of ions (abundance) versus m/z.
2
Example Mass Spectrum
3
Ionization Methods
4
EI Electron Impact
Vapor-phase sample molecules are bombarded with
high energy electrons (70 eV). This causes the
sample molecules to eject an electron forming a
radical cation. Ionization potential of typical
compound lt 15 eV. Therefore, extensive bond
breaking occurs resulting in smaller cations and
radicals.
5
Example of EI MS
6
CI Chemical Ionization
Chemical ionization is a soft ionization
method. Much less bond breaking occurs than in
EI. Vapor phase sample molecules are mixed with a
reagent gas such as CH4, or NH3. The reagent gas
molecules are ionized by electron impact and then
the resulting molecular ions of the reagent gas
molecules react with the sample molecules. R e
? R. 2e R. RH ? RH R. RH S ? SH
R RH S ? RSH (R reagent, S sample, e
electron, . radical electron , H hydrogen)
SH iis the sample molecule plus one proton
m/z M1 It is not a radical-cation (it is an
even-electron species) and was not produced by
excess ionizing voltage. It remains relatively
intact does not fragment.
7
Example of CI MS
8
FAB Fast Atom Bombardment
Uses high-energy (6-10keV) Xe or Ar atoms to
bombard samples dissolved in a high-boiling
liquid (matrix often glycerol). Results in
protonated sample molecules (MH) with little
fragmentation. Also see peaks due to matrix
ionization and subsequent reactions. Useful for
high MW compounds that will not work under CI or
EI conditions.
FD Field Desorption
Carbon microneedles on the surface of a metal
emitter with which sample molecules come in
contact. High voltage gradients at the tips of
the microneedles remove an electron from the
sample molecule which is repelled away from the
emitter. Molecular ions with little excess energy
are generated.
9
Example of FD MS
10
ES Electrospray
11
ES MS of a Protein
12
Ionization Methods Summary
13
Ion Separation Methods
14
Rotating Sector
15
Quadrupole
16
Ion Trap
http//www.chm.bris.ac.uk/ms/theory/qit-massspec.h
tml
17
Summary of Mass Analyzers
http//masspec.scripps.edu/information/intro/chapt
er3.html
18
High Resolution - HR MS
  • Determination of exact mass using HR MS has
    mostly supplanted combustion analysis as a way of
    proving molecular formula for new compounds.

Selenium 79.916250
19
Example
HRMS FAB 542.1203
Write a Comment
User Comments (0)
About PowerShow.com