Description:

one module HV off: Module 5. Problem with Field Ramp. and Beam Dump? Calibration Data: Dedicated Run. Mip Peak: Used for Relative. Energy Calibration. ... – PowerPoint PPT presentation

Number of Views:32
Avg rating:3.0/5.0
Slides: 10
Provided by: star87
Learn more at: https://www.star.bnl.gov
Category:
Tags: emc | barrel | dump | star | the | update

less

Transcript and Presenter's Notes

Title: Star Barrel EMC Update


1
Star Barrel EMC Update
  • Stephen Trentalange
  • UCLA
  • January 18, 2003

2
Tower Timing Curve
3
Installation for 2003
EMC 50 Installed 60 EMC Modules Installed All
PMT Boxes All Electronics 60 SMD Modules
Installed All Electronics Level Zero Trigger
Installed High Tower Jet Patch
4
Installation for 2003
  • EMC Dead Channels
  • 2400 PMTs 32 Uncalibrated (bad electronics)
  • 3 Dead (bases or phototubes)
  • SMD Dead Channels
  • 1800 wire pairs 8 Broken wires 6 repaired-gt 2
    new
  • one reset
  • one module HV off Module 5
  • Problem with Field Ramp
  • and Beam Dump?

5
Calibration Data Dedicated Run
Adjust Voltages to Compensate For Variation of
Gain with Eta Uniformity of Trigger.
Mip Peak Used for Relative Energy Calibration.
6
PMT Gain Equalization
7
Planned Gain Adjustment
Desired Gain
8
High Tower Trigger
Problems
9
Commissioning Tasks
  • Energy calibration with new PMT Voltages
  • SMD Readout Problems
  • SMD Timing
  • Commission High Tower and Jet Triggers
Write a Comment