Title: Piezoelectric Materials


1
Piezoelectric Materials
  • Derek Sanderson
  • Tulane University Chemical Engineering
  • Advisor Prof. Keith Bowman

2
Cancerous Tissue Ablation
  • Idea
  • array of ultrasound transducers
  • concentrate energy
  • destroy cancerous tissue
  • Needs
  • ablation strength pulse
  • Restrictions
  • close proximity
  • small size
  • internal body temp

3
Perovskite Structure
  • Simple cube of As face-centered Cs
    body-centered B
  • A B C
  • Pb2 (Zr/Ti)4 O32-
  • cubic
  • central B-site cation
  • paraelectric
  • not lowest energy
  • tetragonal/rhomb.
  • shifted B-site cation
  • ferroelectric
  • lower energy

4
Microscopic
  • cubic structure at high temp.
  • cooling below Curie temp. (Tc)
  • tetra./rhomb.
  • non centrosymmetric
  • c/a lt 1.005

5
Macroscopic
  • neighboring dipoles align to form domains
  • 6 possible domains per grain
  • infinite possible domains per species ? random
    orientations ? no net dipole ? not piezoelectric

6
Poling
P
x
  • strong field applied
  • field removed net dipole recedes slightly
  • not all domains within a grain will switch

7
Poling contd- XRD
8
Hysteresis
  • Initial polarization (virginal)
  • saturation polarization
  • remanent polarization
  • shows a barrier in displacement of B-cation
  • proof of mechanism for piezoelectricity
  • application of AC causes vibration

Hysteresis curve for Philips PXE 52
9
Piezoelectricity
  • Direct Effect
  • mechanical strain ? electrical pulse
  • Sensors- proportional response
  • force, engine knocking, crash, microphones
  • Generators- conversion of energy
  • igniters
  • Converse Effect
  • electrical pulse ? mechanical strain
  • Actuators- proportional response
  • fuel injection valve, speakers
  • Transducers- conversion of energy (high intensity
    ultrasound)
  • medical imaging
  • tissue ablation

10
PMN-PZT
  • Pb (Mn,Nb) O3 Pb (Zr,Ti) O3
  • (soft) (hard)
  • xPMN-(1-x)PZT ceramic system
  • No mean value theorem

11
Equipment
  • Berlincourt meter- d33 tester
  • Pennebaker Model 8000
  • design and operation

12
Setup
  • Set Parameters
  • tightness of clamp 105o
  • calibration set for post-warming
  • interval time (min) 1,5,15,60 for 30 sec.
  • cooling time
  • Variables
  • warming time
  • sample thickness, weight, atmosphere

13
Results
14
Results
15
Results
16
Results
17
Results
18
Current Theory
  • Possible Explanations
  • operator error
  • reproduced
  • equipment error
  • unknown phenomenon

19
Current Theory
  • Equipment Error
  • Values of d33 are significantly lower (up to 50)
    of reported values by Keramos.
  • Keramos has noticed the same decrease but not
    further investigated
  • Tests to be conducted at Keramos with 2 different
    models of Berlincourt meter

20
Future Work
  • Conclude decreasing piezoelectric constant due to
    equipment error
  • Determine cause of the defect
  • Prepare method of obtaining accurate d33 values
    with current Pennebaker model

21
Acknowledgements
  • Dr. Keith Bowman
  • Thomas Key
  • Piezo Technologies- Keramos Division
  • NSF REU Grant

22
Questions?