Title: Seminar on Concrete Damage Assessments, Concrete Repair and Concrete Mix Technology
1Seminar on Concrete Damage Assessments, Concrete
Repair and Concrete Mix Technology
- Use of Vapour Phase Corrosion Inhibitor
Capsules for Long Term Protection of Repaired
Reinforced Concrete StructuresMr. Brian Davies,
XQ International, Bristol, UK
- Organiser Hong Kong Concrete Institute
- Co-organisersThe Hong Kong Institution of
Engineers (Building Division)Hong Kong Concrete
Repair AssociationDepartment of Civil and
Structural Engineering, The Hong Kong Polytechnic
University
2Corrosion Inhibitors History and Types
- Use to protect steel for over 50 years
- Widely used in reinforced concrete since 1980s
- Types
-
- Integral or cast in corrosion inhibitors (ICI)
- Surface applied migratory corrosion inhibitors
(MCI) - Vapour phase corrosion inhibitor capsules (VPCI)
3Corrosion Inhibitors Do they work?
-
- Integral or cast in corrosion inhibitors (ICI)
- Yes, but dosage is critical
- Surface applied migratory corrosion inhibitors
(MCI) - Yes ?, but highly dependent on porosity and
correct application rate and method - Vapour phase corrosion inhibitor capsules (VPCI)
- Yes, but spacing must be controlled
4Vapour Phase Corrosion Inhibitors How they work
- VPCI capsule is inserted into 25mm holes
which are drilled in the structure to be
protected.
5Vapour Phase Corrosion Inhibitors How they work
- Three separate inhibitors are released over
time as a vapour that saturates a given airspace,
this vapour forms a mono-molecular coating on
embedded steel. The product travels easily
through concrete to coat embedded reinforcement
at a rate of around 1m per week.
6Do Vapour Phase Corrosion Inhibitors Protect
Steel?Simple Nail Test
- 2 nails were sealed in test tubes in 1995, these
pictures were taken in 2007, the example on the
left had no VPCI and the one on the right had
VPCI added. - The corrosion to the nail on the left is
significant, the nail on the right shows very
little corrosion and the tip of the nail is still
shiny.
7Do Vapour Phase Corrosion Inhibitors Protect
Steel?Further Evidence
May 17, 2007
May 22, 2008
8Do Vapour Phase Corrosion Inhibitors Protect
Steel?Laboratory Tests Steel in Concrete2
calcium chloride, 6 months duration
9Future Testing
- Measurement of VPCI travel in large scale
laboratory prepared samples and adsorption
measures using gas chromatography - Intertek
- Testing to NACE TM 0294-2001, Testing of embedded
current anodes for use in cathodic protection of
reinforced concrete, modified for use with VPCI - The Technology Centre (Taywood Engineering)