1
Life Test Effects on the Aeroflex ViaLink FPGA
  • Ronald Lake
  • Aeroflex Colorado Springs

2
Purpose of Investigation
  • Industry is currently evaluating long term
    reliability of antifuse products
  • Aeroflex is proactively reviewing long term
    reliability of RadHard Eclipse ViaLink products
  • Burn-in
  • Low Temperature Operating Life (LTOL)
  • High Temperature Operating Life (HTOL)
  • Accelerated Voltage
  • Monitor

3
Techniques for Long Term Reliability Analysis
  • Accelerated burn-in unprogrammed devices
  • Chamber temperature 125ºC
  • Stress pattern dynamic, 1MHz, production
    unprogrammed device test
  • Duration 16 hours
  • Stress voltages 4.1V I/O 3.2V core
  • Test room temp unprogrammed electrical test,
    read and record
  • Low temperature operating life (LTOL) programmed
    devices
  • Chamber temperature -65ºC
  • Stress pattern dynamic, 1MHz, 10K vectors, high
    toggle rate
  • Duration 500 hours (read point at 24hrs, 168hrs)
  • Stress voltages 3.3V I/O, 2.75V core
  • Test 3 temp electrical test, read and record
    data

4
Techniques for Long Term Reliability Analysis
  • High temperature operating life (HTOL)
    programmed devices
  • Accelerated HTOL
  • Chamber temperature 125ºC
  • Stress pattern dynamic, 10K vectors, high toggle
    rate
  • Duration 500 hours (read point at 96hrs)
  • Stress voltages 4.1V I/O, 3.2V core
  • Test 3 temp electrical test, read and record
    data
  • HTOL monitor - replicates customer use conditions
  • Chamber temperature 125ºC
  • Stress pattern dynamic, 10K vectors, high toggle
    rate
  • Duration 1000 hours (read point at 500hrs)
  • Stress voltages 3.3V I/O, 2.5V core
  • Test 3 temp electrical test, read and record
    data

5
Stress Voltage Margin
  • Operating voltage (functional operation)
  • 2.7 V core
  • 3.6 V I/O
  • Absolute Maximum
  • 3.6 V Core
  • 4.6 V I/O
  • Aeroflex Accelerated Voltage Stress Results
  • QL6325 used for evaluation (in plastic pkg)
  • 4.7 V Core (pass ET)
  • 4.9 V Core (Fails ET)
  • 5.5 V I/O (pass ET)
  • 6.0 V I/O (Fails ET)
  • No Auto Programming of ViaLinks Detected
  • Un-programmed Devices used for this evaluation

6
Reliability Design for Life Test Effects
7
Reliability Design for ViaLink Lifetest
  • Goal Verify long term reliability of programmed
    and un-programmed vialinks with HTOL and LTOL
    tests
  • Design
  • Create worst case design, beyond customers
    ability
  • Use all FPGA logic, memory and I/O resources
  • Use all wiring types, with associated ViaLinks
  • Worst case design constraints
  • Force fan-out 16 (user restricted to
    fan-out10)
  • Force fixed placement to drive long interconnects
  • Force use of worst case ViaLinks with fixed
    placement
  • Disable automatic buffering
  • Use design structures which may be toggled
    efficiently during life test

8
Resource Utilization for Reliability Design
Utilized cells (preplacement) 1533 of 1536
(99.8) Utilized cells (postplacement) 1514 of
1536 (98.6) Utilized Logic cell Frags
(preplacement) 7195 of 9216 (78.1) Utilized
Logic cell Frags (postplacement) 7195 of 9216
(78.1) Utilized Fragment A 1164 Utilized
Fragment F 1302 Utilized Fragment O 1393
Utilized Fragment N 1056 IO control cells
16 of 16 (100.0) Clock only cells 9 of 9
(100.0) Bi directional cells 99 of 99 (100.0)
RAM cells 24 of 24 (100.0) PLL cells 0 of
4 (0.0) Flip-Flop of IO cells 70 of 316 (22.2)
1st Flip-Flop of Logic cells 1097 of 1536
(71.4) 2nd Flip-Flop of Logic cells 1183 of
1536 (77.0) Routing resources 64210 of 119431
(53.8) ViaLink resources 57098 of 3213992
(1.8)
9
Reliability Design Utilization With Customer
Design Flow
Utilized cells (preplacement) 1533 of 1536
(99.8) Utilized cells (postplacement) 1536 of
1536 (100.0) Utilized Logic cell Frags
(preplacement) 8033 of 9216 (87.2) Utilized
Logic cell Frags (postplacement) 8288 of 9216
(89.9) Utilized Fragment A 1536 Utilized
Fragment F 1534 Utilized Fragment O 1447
Utilized Fragment N 1491 IO control cells
16 of 16 (100.0) Clock only cells 9 of 9
(100.0) Bi directional cells 99 of 99 (100.0)
RAM cells 24 of 24 (100.0) PLL cells 0 of
4 (0.0) Flip-Flop of IO cells 70 of 316 (22.2)
1st Flip-Flop of Logic cells 1097 of 1536
(71.4) 2nd Flip-Flop of Logic cells 1183 of
1536 (77.0) Routing resources 65777 of 119431
(55.1) ViaLink resources 57520 of 3213992
(1.8)
10
Reliability Design Shift Register Details
11
Reliability Design Combinatorial Blocks Detail
12
Reliability Design Fixed Worst Case Placement
Constraints
13
Reliability Design Short Path Placement
14
Reliability Design Combinatorial Fan-out
15
Reliability Design Worst Case Fan-out
16
Reliability Design LTOL / HTOL I/O Overshoot and
Undershoot
17
Reliability Design Expanded View LTOL / HTOL I/O
Overshoot
18
LTOL Current Deltas
Current Measurements for HTOL / LTOL Material
19
Summary
  • Worst case design created to evaluate long term
    ViaLink reliability
  • Programmed and un-programmed ViaLinks evaluated
    through low temperature operating life (LTOL) and
    accelerated high temperature operating life
    (HTOL)
  • Data to date shows no ViaLink damage during
    lifetest
  • No functional failures
  • No increase in quiescent or active current
Write a Comment