Hydraulic Engineering - PowerPoint PPT Presentation

1 / 14
About This Presentation
Title:

Hydraulic Engineering

Description:

Hydraulic Engineering Prof. Zaher Kuhail Eng. Tamer Eshtawi Lecture 12 Water Pump Safety systems on pipelines to avoid (water hummer) Pump Inertia Bypass Reflex Valve ... – PowerPoint PPT presentation

Number of Views:621
Avg rating:3.0/5.0
Slides: 15
Provided by: upEduPso
Category:

less

Transcript and Presenter's Notes

Title: Hydraulic Engineering


1
Hydraulic Engineering
  • Prof. Zaher Kuhail
  • Eng. Tamer Eshtawi

2
Lecture 12
  • Water Pump

3
Safety systems on pipelines to avoid (water
hummer)
4
  • Pump Inertia
  • Bypass Reflex Valve
  • Surge Tanks

5
  • Discharge Tanks
  • Reflex Valve

6
Water Pump
  • Water pumps are devices designed to convert
    mechanical energy to hydraulic energy. They are
    used to move water from lower points to higher
    points with a required discharge and pressure
    head. This chapter will deal with the basic
    hydraulic concepts of water pumps.

7
Hydraulic Analysis of Pumps and Piping Systems
Case 1
8
  • hs (static suction head) it is the difference in
    elevation between the suction liquid level and
    the centerline of the pump impeller.
  • hd (static discharge head) it is the difference
    in elevation between the discharge liquid level
    and the centerline of the pump impeller.
  • Hstat (static head) it is the difference (or
    sum) in elevation between the static discharge
    and the static suction heads, .
  • Hms (manometric suction head) it is the suction
    gage reading (if a manometer is installed just at
    the inlet of the pump, then Hms is the height to
    which the water will rise in the manometer).
  • Hmd (manometric discharge head) it is the
    discharge gage reading (if a manometer is
    installed just at the outlet of the pump, then
    Hmd is the height to which the water will rise in
    the manometer).
  • Hm (manometric head) it is the increase of
    pressure head generated by the pump, .
  • Ht (total dynamic head) it is the total head
    delivered by the pump

9
Case 2
10
Case 1
Case 2
Or From Bernoulli
11
Pump Efficiency
  • Which is the power input delivered from the motor
    to the pump
  • Motor which has an the efficiency

which is the power input delivered to the motor.
  • The overall efficiency of the motor-pump system

12
Example 1
Pump with suction pipe diameter of 100mm and
delivery pipe diameter of 75mm, Q in the system
is 15L/s. the manometeric suction head is 198 mm
of mercury, where the manometeric discharge
pressure is 0.95 bar. Motor power is 3.2 KW
13
Solution
14
Efficiency
Write a Comment
User Comments (0)
About PowerShow.com