Anthony Ross Infrared Imaging of Black Liquor Droplets - PowerPoint PPT Presentation

About This Presentation
Title:

Anthony Ross Infrared Imaging of Black Liquor Droplets

Description:

Title: Anthony Ross Black Liquor Droplet Imaging System Author: aaron Last modified by: a Created Date: 12/7/2004 7:00:14 PM Document presentation format – PowerPoint PPT presentation

Number of Views:124
Avg rating:3.0/5.0
Slides: 22
Provided by: Aar49
Learn more at: http://web.cecs.pdx.edu
Category:

less

Transcript and Presenter's Notes

Title: Anthony Ross Infrared Imaging of Black Liquor Droplets


1
Anthony RossInfrared Imaging of Black Liquor
Droplets
Academic Advisor Dr. David Sailor Industry
Advisor Dan Higgins, P.E.
  • Team Members
  • Aaron Brandt
  • Will Carter
  • Brent Illingworth
  • Matt Travis

2
Background
  • Kraft paper pulping process schematic

3
Mission
  • Design an optical assembly
  • Images are used to generate data
  • Data is used to improve boiler model

4
Project timeline
5
Existing sizing techniques
  • Laser Detector Systems
  • Laser passes through spray
  • Photodetectors gather scattered light

6
Existing sizing techniques cont
  • Imaging systems
  • Light focused onto CCD to produce digital image
  • Software analyzes images and outputs size
  • Distance to droplets must be known

7
Sizing technique to be used
  • Infrared imaging system
  • Other systems infeasible
  • Camera currently used for maintenance
  • High contrast due to temperature difference
  • Additional marketability of IR camera

8
Major requirements
  • Depth of focus must be short enough
  • Focal length must be adjustable and known
  • Viewing angle must be adjustable
  • Adequate cooling and cleaning

9
Depth of focus must be short enough
  • Software will only measure droplets that are in
    focus
  • Focal length can accurately be used as the
    distance to droplets
  • Optics aperture affects depth of focus

10
Focal length must be adjustable and known
  • Exact measurement region is unknown
  • Needs to adapt to different boiler configurations
  • Must be known to scale droplet image size to
    actual size
  • Affects depth of focus magnification

11
Focal length adjustment
  • Dual lens system allows for focus adjustment
  • Fine adjustment of rear lens necessary

12
Viewing angle must be adjustable
  • Optics system will be inserted above spray

13
Viewing angle must be adjustable
  • Mirror based system
  • Fiber optics based system

14
Fiber optic imaging
  • Fiber bundles
  • Flexible
  • Coherent
  • Light entering and exiting must be parallel
  • Many components available

15
Viewing Angle Adjustment
  • Bracket assembly
  • Planetary gear assembly

16
Cooling/Cleaning
  • Compressed air on sight
  • Safe to use in boiler
  • Air purge system for lens cleaning
  • Air flow limited by compressed air pressure
  • One or two air ports could be used

17
Decision Matrix
18
Future considerations
  • Optics system
  • Dimensions
  • Calibration
  • Depth of focus
  • Utilize manufacturer expertise
  • Cooling system
  • Detailed analysis
  • Thermal expansion
  • Material selection

19
Conclusion
  • Existing sizing methods analyzed
  • Infrared imaging confirmed as most feasible
  • Major requirements established
  • Possible solutions compared
  • Overall concept decided

20
Complete Concept
21
  • Questions?
Write a Comment
User Comments (0)
About PowerShow.com