NSF-ITR Meeting 10-05 - PowerPoint PPT Presentation

About This Presentation
Title:

NSF-ITR Meeting 10-05

Description:

NSF-ITR Meeting 10-05 Miniaturized Sensors Air molecules aerosols Water molecules cells, viruses Amperometric biosensor using ion channel proteins Amperometric ... – PowerPoint PPT presentation

Number of Views:120
Avg rating:3.0/5.0
Slides: 21
Provided by: GinoBatt
Category:

less

Transcript and Presenter's Notes

Title: NSF-ITR Meeting 10-05


1
NSF-ITR Meeting 10-05 Miniaturized
Sensors Air molecules aerosols Water mole
cules cells, viruses
2
Sensor Operation Sensor Specific Initial event
Transduction to a signal Measurement of
signal Communication of result
3
Initial Event Binding of analyte
Interrogation of free analyte Chemical
reaction
4
Binding of Analyte Gas Chemical or physical
adsorption Metal oxides semiconductors Biolog
icals Antibodies Nucleic acids Ligands
5
Interrogation of free analyte Gas Ionization Sp
ectroscopy Light, microwave, mass Water Spectro
scopy Light, microwave, mass
6
Transduction to a Signal Electrical Conductance
Impedance spectroscopy voltametry Light
Microwaves Absorption Fluorescence Resonance
Oscillators Mechanical motion Surface acoustic
waves
7
Gas Ionization
Modi, et al., Nature, 424, 171-174, 2003
8
Gas Ionization
Modi, et al., Nature, 424, 171-174, 2003
9
Complex Mixtures Difficult to distinguish
components Signal of one component can
swamp others Difficult to standardize
10
A Possible Solution Fractionate the analyte
stream Differentiate molecules based on
size, shape or charge On-chip family of
membranes
11
  • On-chip Family of Membranes
  • Controlled filtration characteristics
  • ?Pattern membrane characteristics
  • ?Biocompatible
  • ?Use with or without electrophoresis

12
Two Membrane Types Under Evaluation
?Cellulose Acetate Spin cast
  • Alumina
  • Nanofabricated

13
Filtration Characteristics vs Preparation
14
Purification DNA from Heme Membrane
electrophoresis
Mohamed, et al., Chromatography A, 2005
15
Proposed Selective Gas Sensor On-chip membrane
ionization
16
An Antibody Based Cell Sensor Binding agent -
immobilized antibody Electrical measurement
- impedance
17
(No Transcript)
18
(No Transcript)
19
Number of captured CD4 cells vs Impedance
Mishra, et al., Biosensors Bioelcectronics,
2005.
20
Amperometric biosensor using ion channel proteins
4 LAYERS 4. Protein sensing component 3.
Lipid membrane provides the proper environment
for the sensor proteins 2. Hydrogel
structural (localization and stability) 1.
Electrode Detection
I
analyte
4
3
2
1
Write a Comment
User Comments (0)
About PowerShow.com