1
TrueSTEAM Humidification Systems
  • Module 4 Advanced Installation

2
Module 4 Advanced Installation
  • Supplemental to Module 3 Basic Installation
  • Additional criteria for
  • Step-by-step instruction
  • Remote installation
  • Installation in finished space
  • Auxiliary plumbing requirements

Key Learning Installing TrueSTEAM in unique
applications
3
Whats in the Remote Kit (50024917)?
A. Insulated hose (10 or 20 ft) B. Remote duct
nozzle C. Remote humidifier nozzle D. Foam gasket
for remote nozzle E. Support hooks (7 or 14) F.
Hose clamps (2) G. Drywall anchors (4) H.
TrueSTEAM screws, 1-1/4 in. (4) I. Support hook
screws, 3/4 in. (7 or 14)
4
Additional Materials May Be Required If
  • Remote hose has a downward slope. You must use a
    212F
  • rated Tee and P-trap. Do not use a plastic Tee.
  • TrueSTEAM is using an auxiliary drain. You must
    install a
  • wetted drain trap or condensate pump rated at
    212F. Pump
  • must have total minimum capacity of 1 gallon
    per minute
  • water flow for the vertical rise of the
    installation.
  • TrueSTEAM is installed in a living space. You
    must install a
  • drip pan with overflow wet switch under the
    TrueSTEAM.

5
Installation Precautions
  • Refer to the remote mount
  • kit installation guide (form
  • 69-2317) for a complete
  • listing of these precautions.

Failure to comply with the installation manual
may result in voided warranty.
6
Tools and Parts Needed
  • Basic tools needed to install TrueSTEAM
  • Wire cutter/stripper
  • Torx driver T-20 and T-30
  • Standard screwdriver
  • 1-3/4-in. diameter hole saw
  • 1/8-in. drill bit
  • 18-gauge wire (up to 5 conductor)
  • Other optional parts for advanced installations
  • Condensate pump rating of 212F (100C) if used.
  • Drip pan with water sensor shut-off required
    underneath TrueSTEAM if installed in or above
    finished space.

7
Step 1 Choosing a Location
Endless Installation Options
8
Step 2 Install Remote Humidifier Nozzle
Remote adapter nozzle should be pitched upward
when installed correctly.
9
Step 3 Mounting TrueSTEAM
10
Step 4 Preparing the Steam Distribution Hose
a.
b.
Insert the hose clamp into the slit and hoot it
onto the rubber hose.
Do not cut into the Rubber steam hose.
11
Step 5 Connecting the Remote Hose
12
Step 6 Plumbing
Use only cold water. Do not use hot water
supply. a. Water Filter. Insert 1/4-inch copper
or plastic water line. Apply modest pull to
ensure a tight fit. b. Back-flow preventer
valve. Insert 1/4-in. copper or plastic water
line. Apply modest pull to ensure a tight fit.
c. Connect 1/2-in. drain tube. Secure drain tube
to barbed fitting with hose clamp. d. Shut off
the water supply. Secure 1/4-in. copper or
plastic water feed tube.
13
Step 6 Plumbing - Auxiliary Plumbing Options
Choose the plumbing option that suits your
installation. Use A, B, C, or D based on type of
pipe or condensate pump. Consult and follow local
plumbing codes in addition to these instructions.
14
Step 6 Plumbing - Auxiliary Plumbing Options
15
Step 6 Plumbing - Auxiliary Plumbing Options
16
Step 6 Plumbing - Auxiliary Plumbing Options
17
Step 6 Plumbing - Auxiliary Plumbing Options
18
Step 6 Plumbing
19
Common Remote Mounting Mistakes to Avoid
c.
d.
b.
a.
a. Sharp hose bends. Horizontal run does not have
minimum pitch of 2 in. per ft. b. Sharp hose
bends. Hose not continuously supported at least
every 12 in., resulting in hose sag. c. Sharp
hose bends. Does not have at least 6 in. vertical
rise immediately out of humidifier, and nozzle is
not pitched up. d. Horizontal run does not have
minimum pitch of 2 in. per ft. Sharp hose bends.
Downward pitch does not have trap at its lowest
point.
20
Support Materials
  • Detailed Training Materials on Installation
    Available!Visit www.forwardthinking.honeywell.co
    mEnter literature form69-2285 TrueSTEAM
    Installation Manual69-2317 Auxiliary Plumbing
    and Installation Options

21
Module 4 Advanced Installation
  • Supplemental to Module 3 Basic Installation
  • Additional criteria for
  • Step-by-step instruction
  • Remote installation
  • Installation in finished space
  • Auxiliary plumbing requirements

Key Learning Installing TrueSTEAM in unique
applications