1QUINT POWER Z
QUINT POWER in especially slim design for systems
and special machine engineering Unique SFB
Technology and preventive function montoring for
superior system availability
2QUINT POWER Z
Quick triggering of the commercial power
circuit-breakers
Dynamic power reserve SFB Technology (Selective
Fusebreaking Technology) with up to six times the
nominal current for 12 ms
Reliable starting of heavy loads
Static power reserve POWER BOOST with up to 1.5
times nominal current continuously
Preventive Function Monitoring
Reports critical operating conditions before an
error occurs, remote monitoring
UPS
Saves up to 50 space in the control cabinet
DC-DC-converter
3QUINT POWER Reliable starting of heavy loads
? Static power reserve
? Up to 1.5 times the nominal current
? Continous up to 40C
? Ca.10 min at 60C
4QUINT POWER Reliable starting of heavy loads
- ? loads are working in parallel
? loads with high inrush currents are starting
- ? The voltage at the PLC should not drop!
PLC running
M
5QUINT POWER Reliable starting of heavy loads
U V I A
PLC-error
UN
IN
without POWER BOOST
t ms
t 1
6QUINT POWER Reliable starting of heavy loads
U V I A
UN
IN
with POWER BOOST
t ms
7QUINT POWER Preventive Function Monitoring
Monitoring the output voltage and current
UoutV
IOUT lt IN
Uout 0.9 x Uout
UOUT gt 0.9 UN
Nominal load
? Power Supply is working with nominal values
Iout A
IN
lt1,5xIN
8QUINT POWER Preventive Function Monitoring
Monitoring the output voltage and current
UoutV
IOUT gt IN
Uout 0.9 x Uout
UOUT gt 0.9 UN
- Detects critical situations before a problem
occurs - output current gt nominal output current
- output voltage remains constant
Iout A
IN
lt1,5xIN
9QUINT POWER Preventive Function Monitoring
Monitoring the output voltage and current
UoutV
IOUT gt IN
Uout 0.9 x Uout
UOUT lt 0.9 UN
- Output voltage
- lt 90 of the adjusted output voltage
Iout A
IN
lt1,5xIN
10QUINT POWER Preventive Function Monitoring
Monitoring the output voltage and current
UoutV
IOUT gt IN
Uout 0.9 x Uout
UOUT lt 0.9 UN
Nominal load
Iout A
IN
lt1,5xIN
11QUINT POWER Quick triggering of power
circuit-breakers
- Maximum system availability due to dynamic power
reserve SFB Technology with up to six times the
nominal current for 12 ms - ? Reliable releasing of standard circuit breakers
- ? Optimal supply of loads with high peak currents
12QUINT POWER Quick triggering of power
circuit-breakers
- ? Short circuit at the contactor coil K1
? Corresponding power circuit breaker triggers
immediately
PLC running
M
- ? The control system as well as all other loads
continue their operation without interruption!
13QUINT POWER Quick triggering of power
circuit-breakers
U V
UN
t
I A
SFB6x IN
K1
IBOOST
IN
t
14QUINT POWER Product overview
1 AC
NEW
NEW
3 AC
NEW
15QUINT POWER Your advantages
Reliable starting of heavy loads
with POWER BOOST
Report the critical operating states before any
error occurs via
Preventive Function Monitoring
Quick triggering of the commercial power
circuit-breakers
with SFB Technology
Saves space in the control cabinet
because of the slim design
Expanded presentation UPS