Title: Hall A Compton Polarimeter For Hall A Collaboration Meeting June 23rd 2005


1
Hall A Compton Polarimeter For Hall A
Collaboration MeetingJune 23rd 2005
  • Sirish Nanda
  • Thomas Jefferson National Accelerator Facility
  • 12000 Jefferson Ave,
  • Newport News, Virginia 23606

2
Hall A Compton Polarimeter
Non-intrusive measurement High current capability
- 30 cm deflection chicane - Detection of
backscattered photons and recoil electrons
15 m
3
Operational Status
  • SRC Experiment
  • High current operation
  • Beam quality monitoring
  • Development tests of integrating DAQ.
  • Trouble begins
  • Laser Power supply/controller failed.
  • Backup power supply incompatible
  • Unable to contact manufacturergt PANIC!
  • Solution
  • Manual calibration of new controller.
  • Rework EPICS control algorithm gt Problem Solved.
  • We no longer have a spare.

4
SRC Expt
5
Counting vs. Integrating
6
Lightwave 1064nm Laser
Controller/PS (in intensive care!)
Laser Head
7
Cavity Lock _at_half power ?
8
(No Transcript)
9
Compton Upgrade Scope
(Cost 250k)
  • Green Laser and Cavity (30 completed)
  • Four-fold increase in figure-of-merit
  • Larger scattering angles gt possible to detect
    electrons at lower energies
  • New Electron detector (5 completed)
  • Finer pitch improves energy resolution
  • Adjustable distance from beam to improve dynamic
    range
  • Integrating Photon DAQ (70 completed)
  • Provides redundancy to photon counting
  • Improved systematics

10
Green Optics Test Setup
11
Laser Safety Issues
  • Jab Safety Standards require a dedicated Green
    laser room
  • Lab management is in the process of get us
    dedicated lab space in the ARC building
  • Until then
  • We have set up a low power (class II, e.g laser
    pointer) setup in the EEL Lab
  • We can study most things at low power
  • Get to know the green Laser and cavity
  • Test setup is now operational in EEL

12
(No Transcript)
13
EEL Green Optics lab (Temporary)
14
Laser Power Response
15
Laser SHG Temp Response
16
Green Near field Beam spot
17
Green Laser beam profiling
18
Green Laser Beam focus
19
Turnkey Polarimeter (Thorlabs)
20
Prometheus lasers beam pol
21
Polarization after FOI/45
22
After QWP
23
Circular Polarization for cavity injection
24
Deepas Prototype cavity
25
Cavity Mirror Mount
26
Beam Injection to Cavity
27
Green beam!
28
Conclusion
  • The present IR Compton laser/cavity is operating
    ok. But needs a functional backup laser, just in
    case
  • The integrating Compton DAQ has made great
    progress. Needs better understanding of
    systematic errors
  • The Green Compton project is moving well. But
    needs help.
  • It desperately needs a dedicated Green Laser lab.
  • I hope to complete the Green Compton Project by
    2007.