Skyline Design Group - PowerPoint PPT Presentation

1 / 4
About This Presentation
Title:

Skyline Design Group

Description:

Skyline Design Group. Bay Optimization. Design Assumptions ... Total bay cost = 6 secondary 1 primary 1 column 30' x 30' slab, WWF, deck. Design Proposal ... – PowerPoint PPT presentation

Number of Views:24
Avg rating:3.0/5.0
Slides: 5
Provided by: RJT5
Category:
Tags: bay | design | group | skyline

less

Transcript and Presenter's Notes

Title: Skyline Design Group


1
Skyline Design Group
  • Bay Optimization

2
Design Assumptions
  • Secondary beams
  • Simply supported
  • Continuously braced (Lb 0)
  • Uniformly loaded
  • Designed for interior beams
  • Primary beams
  • Simply supported
  • Braced 5' o.c. (Lb 5)
  • 5 point loads
  • Columns
  • Directly support load from tributary area
  • Effective length factor, K 1 (diagonal bracing
    present)
  • Bays
  • Uniform bay layout across structure
  • Total bay cost 6 secondary 1 primary 1
    column 30' x 30' slab, WWF, deck

3
Design Proposal
  • BAY SIZE 30' x 30'
  • Deck Slab
  • 1.0C24 steel deck
  • 4" thick slab (t3")
  • WWF 6x6-W2.9X2.9
  • Normal weight concrete
  • Secondary beams
  • W12x26, 30' in length
  • Primary beams
  • W24x84, 30' in length
  • Columns
  • W12x35, 12' high

4
Design Cost