Title: Geant4 Monte Carlo Characterization of Novel Electronic Brachytherapy System


1
Geant4 Monte Carlo Characterization of Novel
Electronic Brachytherapy System
  • Derek Liu
  • E. Poon, M. Bazalova, B. Reniers, M. Evans
  • J. Seuntjens, T. Rusch, F. Verhaegen
  • McGill University
  • Xoft, Inc.

2
Axxent Miniature X-ray Tube
3
Project Objectives
  • Characterize x-ray tube
  • Monte Carlo with experimental verification
  • Beam quality
  • HVL
  • Attenuation curve
  • Photon Spectrum
  • Spectrum
  • 2-D Dose distribution
  • Gafchromic film in Lucite Phantom

4
Attenuation Curve
  • NE 2571 farmer
  • 2 mm Pb collimator
  • 0.5 cm aperture
  • Src-collimator 1
  • Src-Al foil 2
  • Src-detector 10
  • Output fluctuation

Output monitor
  • Beam hardening

Chamber response
  • Scatter

Subtract scatter
5
Spectrum
  • Amp-Tek CdTe
  • 1 mm Crystal
  • 4 mil Be Window
  • 2 mm W collimator
  • 2 mm aperture
  • Src-CdTe 1.5 m
  • Air attenuation

Attenuation correction
  • Detector response

Stripping procedure
  • Energy Calibration

31.0 keV Ba-133 decay 14.9 keV Yttrium K-alpha
6
Geant 4.8.1
  • Why use Geant?
  • Complex geometry
  • Low energy physics
  • C
  • Coding flexibility
  • Geometry
  • Tip thickness 0.2 mm
  • Transmission Tungsten target thickness 0.7 um
  • 2 mm water

7
Geant 4 Bremsstrahlung Production
Bremsstrahlung mean free path
Bremsstrahlung angular distribution
8
Geant 4 Bremsstrahlung Production
9
Source to Source Variation
10
Comparison between Measured Spectra and Geant
11
Source to Source Variation
12
Aging Effects
13
2-D Dose Distribution
  • Gafchromic EBT films
  • Lucite Phantom
  • Src parallel to film
  • Src-film 1.5 cm
  • Exposure time 5 min
  • Max dose 5 Gy
  • Calibration

Ir-192 calibrated in water
  • Film scanning

Document scanner
  • Image registration

Matlab correlation routine
14
Gaf EBT in Lucite Relative Dose distribution at
1.5cm
15
Conclusion
  • Geant4 Bremsstrahlung production comparable with
    EGS
  • Angular distribution
  • Bremsstrahlung mean free path
  • Bremsstrahlung spectrum
  • Spectral measurements
  • Spectra in agreement with Geant4
  • Attenuation curve measurements
  • HVL in agreement with spectral HVL and Geant4
  • Observed factors affecting beam quality
  • Source variation
  • Aging effect
  • Dose distribution measurements
  • General agreement with Geant4
  • Deviation in forward and aft directions

16
Acknowledgement
  • This project is partially funded by Xoft, Inc.
  • CdTe spectrometer funded by Research Institute of
    MUHC