It is absolutely impossible to make all 40 LCLS undulators identical due to variation in the magnet properties and a tolerance stack-up, determining the actual pole gap. - PowerPoint PPT Presentation

1 / 7
About This Presentation
Title:

It is absolutely impossible to make all 40 LCLS undulators identical due to variation in the magnet properties and a tolerance stack-up, determining the actual pole gap.

Description:

XFD XF Engineering Group ... due to variation in the magnet properties and a tolerance stack-up, determining ... XFD XF Engineering Group. Test of the LCLS ... – PowerPoint PPT presentation

Number of Views:23
Avg rating:3.0/5.0
Slides: 8
Provided by: Emi9153
Category:

less

Transcript and Presenter's Notes

Title: It is absolutely impossible to make all 40 LCLS undulators identical due to variation in the magnet properties and a tolerance stack-up, determining the actual pole gap.


1
BASICS
  • It is absolutely impossible to make all 40 LCLS
    undulators identical due to variation in the
    magnet properties and a tolerance stack-up,
    determining the actual pole gap.
  • Our goal is to find during the magnetic tuning
    for each individual undulator the proper beam
    trajectory coordinates (X and Y) for the same
    K-value.
  • Each undulator should be tuned in such a way that
    beam trajectory should be on the intersection of
    the horizontal and vertical planes.
  • X and Y coordinates have to be connected to the
    fiducials for each individual undulator through
    the magnetic needles.

2
How to replace any of the LCLS undulators
  • We are expecting that the variations in x
    coordinates between the different LCLS undulators
    will be within 800 1000 microns and the
    variation in Y coordinate will be within 30 50
    microns.
  • Undulator supporting plates (on each side) have
    vertical and horizontal shims with the sufficient
    thickness to accommodate X and Y coordinate
    variations by grinding.
  • These shims should be precisely ground to get
    dimensions A and B exactly the same for all
    undulators with the precision 20 30 microns for
    the dimension B and 50 70 microns for the
    dimension A.
  • A true kinematic mount is not appropriate in my
    opinion . It will decrease rigidity of the whole
    structure without any benefit.

3

4
HOW TO MAKE ALL LCLS UNDULATORS IDENTICAL
5
SUPPORT ADJUSTING SHIMS EXPLODED VIEW
6
SUPPORT ADJUSTING SHIMS
7
CONCLUSION
  • Test of the LCLS undulator replacement will be a
    part of SUT.
  • We intend to remove the dummy undulator off the
    girder and bring it back 5-6 times and verify
    optically and with the use of KEYENCE non-contact
    laser measurement the precision and repeatability
    of replacement.