Thermolag Tel: 011 397 4556 Fax: 011 397 4509 - PowerPoint PPT Presentation

1 / 2
About This Presentation
Title:

Thermolag Tel: 011 397 4556 Fax: 011 397 4509

Description:

... are designed to match operating conditions for both continuous service - and ... Under certain conditions the Thermospan expansion joint can handle movements ... – PowerPoint PPT presentation

Number of Views:23
Avg rating:3.0/5.0
Slides: 3
Provided by: janicew7
Category:

less

Transcript and Presenter's Notes

Title: Thermolag Tel: 011 397 4556 Fax: 011 397 4509


1
Thermolag Tel (011) 397 4556Fax
(011) 397 4509 E-mail thermolag_at_kapaf.co.za
Malcolm Moodie CrescentJet Park
ThermospanExpansion Joint - Flanged Geometry
Typical Flanged Rectangular Joint CornerA Max
150 mmB Variable not to exceed 150 mmC 50 mm
Breach Opening
Flow
Slots 25 x 18
A
B
C
A
A
B
50
Bolt B/M
Duct O.D.
Thermospan Expansion Joint with optional Bolster
Belted Geometry
Typical Belted Rectangular Expansion Joint
CornerA 100B Variable not to exceed 100C
50
Flange width
Bolster
Breach Opening
Flow
Expansion Joint
150 Radius at corner
Set Back
Duct O.D.
2
Thermospan Expansion Joints
Thermospan fabric expansion joints are
custom-made for ducting applications where high
temperature, moderate pressure, high abrasion and
adverse chemical conditions apply. All unusual
situations can be referred to Thermolag for
recommendations. Our design engineers are
available to give assistance in the field.
APPLICATIONS Thermospan expansion joints excel in
power generating plants in dry gas systems. They
are also recommended for high-temperature exhaust
gas systems in process plants, paper mills, steel
mills, foundries, cement mills and in refinery
and chemical plant applications that use
scrubbers and precipitators. These compensators
are suitable for vibration isolation of forced
draft and induced draft fans. BAFFLING Internal
baffles may be required to protect the inner ply
from abrasive effects of particles. Thermolag
will supply these plates.
SERVICE Thermospan expansion joints in the 150C
900 C range are used primarily on the cool
side of the flue system or process lines where
gas temperatures climb above the condensation dew
point. Thermospan expansion joints are designed
to match operating conditions for both continuous
service - and excursion temperatures.
EXTERNAL INSULATION Thermospan expansion joints
contain their own internal insulation, therefore
no external insulation is required. If external
insulation is applied, it will severely limit the
operating exclusion temperature capabilities.
THERMOLAG CONTACT DETAILSTel (011) 397 4556
Fax (011) 397 4509 E-mail
thermolag_at_kapaf.co.za
Write a Comment
User Comments (0)
About PowerShow.com