Title: Comparison of visual function following piggyback implantation of Acrysof ReSTOR intraocular lenses with Tecnis multifocal ZM900 intraocular lenses.
1Comparison of visual function following piggyback
implantation of Acrysof ReSTOR intraocular lenses
with Tecnis multifocal ZM900 intraocular lenses.
Rodrigo Vaz, MD Leonardo Akaishi, MD Patrick F.
Tzelikis, MD
None of the authors has a financial or
proprietary interest in any material or method
mentioned.
2Purpose
- To compare the postoperative outcome of piggyback
implantation using the AcrySof ReStor lens with
Tecnis ZM900 multifocal intraocular lenses (IOL).
3Material / Methods
- This prospective comparative study included
patients with age-related cataract, primary
hyperopia or hyperopic astigmatism, a normal
ophthalmologic examination besides senile
cataract, and unsatisfactory correction with
glasses. - Information collected included uncorrected visual
acuity (UCVA) for near and distance, best
corrected visual acuity (BCVA), and spherical
equivalent (SE) before and after the surgery. - All patients were followed for 6 months
4Material / Methods
- The three lenses used in this study were TECNIS
ZM900 multifocal IOL, AcrySof ReStor and
CLARIFLEX. - The multifocal IOL (Tecnis ZM900 or AcrySof
ReStor) was first implanted in the capsular bag
and the Clariflex lens was implanted second in
the ciliary sulcus.
5Material / Methods
- The TECNIS multifocal IOL (Model ZM900, AMO,
Santa Ana, CA) is a 3-piece diffractive
multifocal lens with 6.00 mm polysiloxane optic. - The AcrySof ReSTOR (Model SA60D3, Alcon
Surgical Laboratories, Dallas, Texas) is an
acrylic foldable single-piece IOL. - The CLARIFLEX (Model AMO, Advanced Medical
Optics, Santa Ana, California) is 3-piece
monofocal lens with 6.00 mm biconvex square-edged
silicone optic and 10-degree angulated C
polymethyl-methacrylate (PMMA) haptics.
6Material / Methods
- The Holladay formula was used to calculate the
IOL power when there was a short axial length (lt
22.0 mm) and the SRK/T formula was used when
there was an average axial length ( 22.0 mm).
The A-constant used was 119.8 for the TECNIS
multifocal IOL, 118.6 for the AcrySof ReStor and
118.4 for the CLARIFLEX IOL. Axial length was
measured with the IOL Master (Carl Zeiss Meditec
AG), and the targeted postoperative refractive
error was 0.0
7Results
Teste t Student (SPSS)
Preoperative Tecnis ZM900 (n20 eyes) ReStor (n21 eyes) P value
Axial length 20.80 mm (SD0.80) 21.68 mm (SD0.39) Plt0,001
Power IOL (D) 26.75 D (SD 1.95) 22.0 D (SD 1.75) Plt0.001
UCVA 0.08 (20/250) (SD 0.11) 0.25 (20/80) (SD 0.06) Plt0.001
BCVA 0.67 (20/30) (SD 0.08) 0.9 (20/22) (SD 0.17) P0.02
SE 6.25 D (SD 2.25) 4.25 D (SD 1.55) P0.002
8Results
Teste t Student (SPSS)
Postoperative (6 months) Tecnis ZM900 (n20 eyes) ReStor (n21 eyes) P value
UCVA for distance 0.67 (20/30) (SD 0.15) 0.86 (20/23) (SD 0.16) P0.002
UCVA for near 33 cm J1 J1 P0.14
BCVA for distance 0.90 (20/22) (SD 0.10) 1.00 (20/20) (SD 0.05) P0.002
BCVA at 60 cm J4.5 J5 P0.08
SE 0.00 D (SD 0.45) -0.25 D (SD 0.40) P0.06
9Results
10Results
- After a follow-up of 6 months, halos were
reported as severe by 8.3 , moderate by 33.3
and absent or mild by 58.4 of patients in the
Tecnis group. In the ReStor group halos were
reported as severe by 9.0, moderate by 27.3
and absent or mild by 63.7. - No interlenticular opacification (ILO) or another
postoperative complication related to piggyback
lenses was observed in our series.
11Conclusion
- Overall, the use of a multifocal IOL in a
piggyback fashion appears to be a safe and
efficient procedure and a good refractive
solution. - Implanting 2 piggyback IOLs was beneficial in
eyes with short axial length. The AcrySof ReSTOR
IOL gave better outcomes than the Tecnis
multifocal IOL in UCVA and BCVA for distance,
probably because in the Tecnis group the eyes had
shorter axial length and required higher diopter
lenses.