Chemistry Research Laboratory Energy Management
Performance
  • Philip Pike
  • Energy Conservation Engineer

2
Facts Figures
  • 15,500m² GIA
  • Largest lab, third largest building
  • Largest boiler capacity
  • Largest electricity supply
  • Potentially the most energy hungry

3
Electricity - Consumption
  • Design estimate 290kWh/m²
  • Actual (Feb June) 355kWh/m²
  • Old Chemistry Labs 210 - 260kWh/m²
  • Biological Sciences 320 - 610kWh/m²

4
Electricity Estimated Energy Splits
  • Percentage Load (kWh/m²)
  • Pumps 3 9
  • Fans 43 52
  • Cooling 18 125
  • Lighting 9 25
  • Miscellaneous 25 73
  • Lifts 2 6

5
Electricity - Loads
  • Average load 628kW
  • Maximum load June 1377kW
  • Minimum load June 417kW
  • Weekday load 800kW
  • Weekday night load 450kW
  • Weekend day load 660kW

6
Electricity Demand June 2004
7
Electricity Consumption
  • Ventilation fans Labs run longer
  • Pumps run constantly
  • Chillers constant CW demand
  • Lighting (local controls)
  • Essential services - 25kW constant

8
Gas
  • Design estimate 527kWh/m²
  • Actual estimate 395kWh/m²
  • Biological Sciences 847kWh/m²

9
Gas Consumption
  • Four 1750kW LTHW boilers
  • Four 26kW hot water heaters
  • No sub-meters
  • LTHW on continuously for reheat

10
Water
  • Design estimate 72,000m³/yr
  • Actual use (Feb June) 42,000m³/yr
  • Equates to 2.7m³/m²
  • Old chemistry buildings 5.5 10.1m³/m²
  • Process cooling water
  • Electric vacuum pumps
  • High lab water pressure