Title: Some comments on ESTB static and dynamic DC in Lisboa
1Some comments on ESTB static and dynamic DC in
Lisboa
2ESTB DC in Lisboa-outline
- static measurements comparison
- outputs
- performance
- dynamic measurements
- procedure
- doubt on TTC
- performance example
- conclusion ?
3Static measurements comparison
- comparison between
- NovAtel OEM 3 DL receiver
- Septentrio PolaRx-2
- Rx own output
- with WinGPSAll
- example of September 25th
- Septentrio integrity case
4Static measurements comparisonHPE - Sep 25
5Static measurements comparisonVPE - Sep 25
6Static measurements comparisonHPL - Sep 25
7Static measurements comparisonVPL - Sep 25
8Static measurements comparisonSeptentrio
integrity unit ?
- up to 7 August
- Up to 7 August the XPL data file contains the HPL
and VPL in meters and, normally, both are
slightly higher than those produced by WinGPSAll
- report from EUROCONTROL / Victor
Alvarez-Cotroff - after 7 August
- From 14 August the values in XPL data file are
much bigger than those provided by WinGPSAll and
we assume that the presented values are in feet
????
9Septentrio integrity unit ? horizontal
protection levels
10Septentrio integrity unit ? vertical protection
levels
11Dynamic measurements with TTC
- doubts about TTC
- performance example
12Dynamic measurementsprocedure
- 2 reference stations available
- IST reference station
- AT1 reference station (static DC location)
- example flight ILS calibration in Lisbon
- Truth-reference generation
- Trimble Total Control
- performance analysis
13Dynamic measurementsexample horizontal path
dE (km)
dN (km)
- example of ILS calibration trajectory at Lisbon
Airport - AT1 ref.
- Novatel OEM3 TB Rx
- 30 may 2003
14Dynamic measurementshorizontal errors single
ref.
North error (m)
latitude (deg)
- IST as ref. station
- correlation
15Dynamic measurements horizontal errors both ref.
North error (m)
latitude (deg)
ISTAT1 ref. station
16Dynamic measurementsTTC problem ?
- with single ref. horizontal errors (up to 30m !)
- proportional to distance to reference ?
- verification with a static measurement at AT1
- using standard static procedure
- using dynamic procedure with TTC
- using IST as reference station (5km from AT1)
- using Cascais as reference station (27km from AT1)
17Dynamic measurementsstatic verification
N,E errors proportional to N,E distance to ref. ?!
18Dynamic measurementsperformance analysis
19Dynamic measurementsperformance summary (May
30th)
- HPE / HPL 2.2 / 13.2 m
- VPE / VPL 2.8 / 20.7 m
- HOR - CAT-I 100
- VER - APV-I 100 APV-II 92.1 CAT-I 46.8
- no LOI events / no interruption
- limited performance but similar to static results
of same period
20reaching some conclusions ?
- Still some doubts on the tools and procedures
used in this evaluation