Choosing the right fire alarm initiation devices Having a company like Quickshipfire who has made it their business to know the ins and outs of these systems and devices is essential to effectively protecting your property and those who live or work there. Don't let the safety of your family and property be compromised - contact Quickshipfire today for information on best fire alarm parts. As one of the top fire alarm equipment suppliers in the USA, Quickshipfire provides high-quality fire alarm systems. We will assist you in selecting fire alarm components, fire alarm batteries, or replacement fire alarm parts that will provide the best protection for your people and property. – PowerPoint PPT presentation

Number of Views:3
Slides: 4
Provided by: quickshipfire
Tags:

less

Transcript and Presenter's Notes

Title: Different Types of Fire Alarm Initiating Devices


1
  • Different Types of Fire Alarm Initiating Devices
  • The fire alarm initiating devices in a fire alarm
    system detects signs of fire and activates an
    alarm. They are the system's triggers and its
    most visible element.
  • Initiating devices are connected to the alarm
    systems control panel via 2- or 4-way circuits
    and are under the control panels constant
    surveillance. In the event of an activation of an
    initiating device, the panel determines the
    activation and goes into an alarm state, sounding
    the alarm in the building and alerting the
    emergency service provider.
  • The most common fire alarm initiating devices are
    smoke detectors, sprinkler water flow switches,
    manual pull stations, and more.
  • Various types of fire alarm initiation devices
  • Initiating devices can be classified into two
    categories automatic initiating devices and
    manual initiating devices.
  • Automatic initiating devices
  • Automatic initiators are those that are triggered
    automatically as soon as the appropriate
    conditions are met. They include
  • Smoke detectors
  • Fire sprinkler water flow switches
  • Heat detectors
  • Automatic initiating devices come in spot type
    and linear type.
  • A spot detector focuses only on the area where it
    has been installed, whereas a linear device
    covers a wide area of space but communicates with
    a single control unit. A standard ionization
    smoke detector is an example of a spot type,
    while a light-obscuration photoelectric smoke
    detector is an example of a linear type.
  • Spot types are less expensive, but their
    connections to fire alarm systems must be made
    separately, and more devices are needed to
    adequately cover an area. While linear types are
    more expensive, they only require one connection
    to the fire alarm system, and one unit covers a
    larger area.

pull stations are, of course, meant by this.
2
As soon as one of these devices is activated by
their respective conditions (smoke, heat, water
flow, or manual adjustment), the control panel
detects the change and initiates the alarm, which
triggers a visual and audible alarm to alert
building occupants. What does the fire alarm
initiation devices do? In most fire alarm
systems, there are multiple types of initiating
devices, each with its own role and triggering
requirements. It is necessary to install each
initiating device separately and connect it to
the circuitry of the fire alarm system. Below is
the brief explanations of how each type of
initiating device works Smoke
Detectors Initiating devices like smoke detectors
help fire alarm systems respond quickly before a
fire has the chance to develop fully. It is
because fires cause smoke early on in their
development, long before water sprinklers or heat
detectors activate. The two most common types of
smoke detectors are ionization and
photoelectric. Ionization smoke detectors measure
airflow current using ionized air held within a
sensing chamber. As smoke penetrates the chamber,
it reduces the current. The detector activates
when the current drops enough. A photoelectric
smoke detector detects smoke by using light in
one of two ways. A light-scattering method
involves arranging a light source and sensor
(both within the detector) such that the sensor
cannot detect the light under normal conditions.
When smoke enters the detector, it scatters or
reflects light back into the detector. The sensor
is activated when enough light hits it. The
second photoelectric method is light obscuration,
in which the light source and detecting sensor
are usually separate components. When a light
beam is projected into the sensor, the sensor
remains inactive as long as it receives the
light. In the event that smoke from a fire
obscures the light beam from the sensor, the
detector will be activated.
Sprinkler Water Flow Switches Sprinkler water
flow switches detect the flow of water through
the pipes of a fire sprinkler system. The water
in the pipes of a sprinkler system typically sits
stagnant when it isn't activated. When a fire
sprinkler is activated by a fire-induced
temperature, water flows through its system and
out of its open end. A sprinkler water flow
switch detects this change in water activity and
alerts the fire alarm control
panel that the sprinkler system has been
activated.
3
Heat Detectors Heat detectors are the oldest
automatic initiating devices and are still the
most reliable, though they are slow to respond to
fires. The most common types are fixed
temperature detectors and rate-of-rise
detectors. Fixed-rate heat detectors activate
when the room temperature reaches a specific,
predetermined level. In the event of a fire, it
can take a long time before the temperature
reaches this predetermined level, so the
initiating device may not respond for some time
after a fire has started. In contrast, a
rate-of-rise heat detector activates when the
temperature around it rises 15 degrees or more in
a minute. As a result of this rapid increase in
temperature, the air inside the detector's
chamber expands, pressing a metal diaphragm
against contacts that trigger the detector's
activation. Manual Pull Stations As portrayed
in many films, manual pull stations allow
individuals to initiate the fire alarm in case of
an emergency. There are two types of pull
stations single-action and dual-action.
Single-action stations require only one physical
action pulling a lever. A dual-action station,
on the other hand, requires two actions, such as
breaking a glass cabinet containing the lever or
lifting a covering. Choosing the right fire
alarm initiation devices Having a company like
Quickshipfire who has made it their business to
know the ins and outs of these systems and
devices is essential to effectively protecting
your property and those who live or work
there. Dont leave the protection of life and
property to chance give Quickshipfire a call
today to know about best fire alarm parts.
Quickshipfire is one of the best fire alarm
equipment provider companies in USA. We will help
you to choose the right fire alarm components,
fire alarm batteries or replacement of fire alarm
parts that will best protect your people and
property. https//quickshipfire.com/