IMAGE RECEPTORS - PowerPoint PPT Presentation

1 / 12
About This Presentation
Title:

IMAGE RECEPTORS

Description:

IMAGE RECEPTORS. Follow the Sequence- Film System. Tube. Patient (bucky) or non-bucky ... Tube. Patient (bucky) or non-bucky. Cassette. IMAGING PLATE ... – PowerPoint PPT presentation

Number of Views:386
Avg rating:3.0/5.0
Slides: 13
Provided by: rae8
Category:
Tags: image | receptors | tube

less

Transcript and Presenter's Notes

Title: IMAGE RECEPTORS


1
IMAGE RECEPTORS
2
Follow the Sequence- Film System
  • Tube
  • Patient
  • (bucky) or non-bucky
  • Cassette
  • INTENSIFYING SCREEN
  • FILM

3
Follow the Sequence- Filmless (CR) System
  • Tube
  • Patient
  • (bucky) or non-bucky
  • Cassette
  • IMAGING PLATE
  • DIGITIZER OR READER
  • MONITOR

4
Follow the Sequence- Filmless (DR) System
  • Tube
  • Patient
  • (bucky) or non-bucky
  • DIGITAL RECEPTOR
  • MONITOR

5
INTENSIFYING SCREEN
  • PG 171
  • When using intensifying screens in cassette the
    exposure to the film is 90 -99 FROM LIGHT
  • Anatomy of a screen
  • Protective layer
  • Phosphor or active layer
  • Reflecting or absorbing layer
  • base

6
PHOSPHORS
  • SPECTRAL EMISSION
  • RARE EARTH
  • HIGH ABSORPTION HIGH CONVERSION EFFICIENCY
  • FASTER SPEED

7
PHOSPHOR THICKNESS, SIZE
  • Impacts screen speed and detail
  • Faster screen less detail less mAs
  • Slower screen more detail more mAs
  • Old screen speed/new screen speed
  • Reflecting layers increase screen speed
  • Light absorbing layer or light absorbing
    dyesdecrease speed but increase recorded detail
  • Table 7-2
  • Quantum Mottle
  • Screen Maintenance

8
Follow the Sequence- Filmless (CR) System
  • Tube
  • Patient
  • (bucky) or non-bucky
  • Cassette
  • IMAGING PLATE
  • DIGITIZER OR READER
  • MONITOR

9
CR cassette
  • Protective layer
  • Photostimulable phosphor
  • Reflective layer
  • Base
  • Backing

10
Barium Fluorohalide crystals coated with europium
  • Phosphor releases some visible light
  • The x-ray energy is absorbed (trapped)
  • Latent image
  • Sensitive to a wide range of energies
  • Erase plate if not used in 48 hours
  • Process within an hour of exposure
  • Increase mAs as CR is equivalent to 200 screen
    speed vs 400 screen speed used in film
    systemswhy?

11
Follow the Sequence- Filmless (DR) System
  • Tube
  • Patient
  • (bucky) or non-bucky
  • DIGITAL RECEPTOR
  • MONITOR

12
DIRECT CAPTURE DETECTOR
  • CCD (CHARGE COUPLED DEVICE)
  • Radiation interacts with the detector (within the
    table, upright chest unit or on a extremity unit)
  • X-rays are either converted to light that reacts
    to a layer of amorphous silver electric charge
  • Or
  • X-rays are interact directly with layer of
    amorphous silver electric charge