NobelActive Internal and External Hex Implants Nobel Marketing Claims this is the Implant of the Future - PowerPoint PPT Presentation

1 / 17
About This Presentation
Title:

NobelActive Internal and External Hex Implants Nobel Marketing Claims this is the Implant of the Future

Description:

NobelActive Internal and External Hex Implants Nobel Marketing Claims this is the Implant of the Future NobelActive is a Conglomeration of Common Features that ... – PowerPoint PPT presentation

Number of Views:470
Avg rating:3.0/5.0
Slides: 18
Provided by: implantdi
Category:

less

Transcript and Presenter's Notes

Title: NobelActive Internal and External Hex Implants Nobel Marketing Claims this is the Implant of the Future


1
NobelActive Internal and External Hex Implants
Nobel Marketing Claims this is the Implant of
the Future
2
NobelActive is a Conglomeration of Common
Features that work individually but not
necessarily in combination
Screw-Vent Internal Hex/bevelNiznick Patent 1986
Astra 11Deg. Bevel
NobelActive hex too deep to allow for 8mm
implant length
45 Deg. Bevel Bevel with proven 20 year history
of stability
Osstems double Threads over entire length.
NobelActive transition of sharp to flat threads
not contusive for self-tapping insertion in
dense bone
Oraltronics Pitt-Easy Implant with Deep Apical
Threads Alpha Bio Clone with Conical Connection
3
NobelActive External -With External Locking
Taper ConnectionNobel Marketing Claims this is
the Implant of the Future
1.5mm High External Hex 3.5mm Morse Taper Post
4
NobelActive External - 5mm high tapered post
requires parallelism Miter Implant with External
Post Evolved quickly to Internal Socket (Bicon)
Those who cannot remember the past are condemned
to repeat it QUOTATION George Santayana
(18631952), U.S. philosopher,
Driskell Patent 1985 Tapered Post on
ImplantLocking taper concept impacting the
female taper of the implant head with the male
counterpart on the root structure.
Driskell Patent 1988 Tapered Socket in
ImplantLocking Taper Concept The head member
has a tapered rod or socket for connection to
the root
5
NobelActive (TiUnite) and Alpha Bios SFB (SLA)
Implants BUT Nobel claims 98.3 Alpha Bio study
applies to its new implant
ABOVE Nobel Claims NobelActive success of 98.3
for up to 4 years BELOW Alpha Bios Catalog
Claims same 98.3 success after more than 5
years but the surface is SLA (sand blasted with
large grit followed by acid etching) like
Straumanns Surface
6
Nobel Claims NobelActive Functions like
Corkscrew Close Evaluation indicates they
should have left it in the bottle
7
Nobel Biocares NobelActive Marketing Claims
NobelActive Marketing Claims
Questionable Validity of Marketing Claims
  • Higher than What Replace? Increased stability
    achieved by spreading bone whereas deep threads
    cut bone
  • Self-threading like any screw in soft bone.
  • Path of implant insertion should be established
    during surgery, not during implant insertion.
    That is what guide pins and end-cutting drills
    are for.
  • Nothing unique about press-fit connection. Miter
    Implant (1980) had external tapered post
    evolved to internal press-fit connection of Bicon
  • If cement is a risk, why does NobelActive
    Internal have a screw-retained connection?
  • Why does NobelActive have spiral cutting grooves
    if not to cut through bone like conventional
    (self-tapping) implants?
  • bone-condensing expands indication range and
    gives even higher initial stability.
  • self-drilling
  • ability to change direction during surgery
  • unique press-fit connection of abutment
  • -removes risk of excess cement
  • NobelActive Internal and External implants dont
    cut through bone like

conventional implants, they press through it like
a corkscrew
8
NobelActive External Claims
Claims are not Valid
  • It is not a one-piece implant requires an
    abutment.
  • Does not have 2-piece flexibility Can not use
    angled heads greater than 12 degrees, ball,
    screw-receiving or ceramic abutments. Require
    parallel placement of implants for bridges.
  • A one-piece implant eliminates micro gap but a
    precise-fitting internal connections maintain
    marginal integrity anyway. Nobel still sells
    external hex implants less stable
  • One piece implant
  • design with 2-piece flexibility
  • locking tapered interface .. Eliminates bone
    level micro gap, micro-movement and the use of
    abutment screws.

9
Dense Bone Drill is 4.6mmD but Platform is
3.9mmDNobelActive Leaves Gap around neck of
Implant in Dense Bone
10
4.3mmD Replace Implant is better choice than
4.2mmD NobelActive for insertion into Immediate
Extraction Sockets
Narrow Neck of NobelActive Requires Bone and Soft
tissue Grafting to fill defect left at crest of
ridge
5.0
5.0
3.9
5.0
11
Compare NobelActive External Hex with ScrewDirect
One-Piece ImplantThe Prosthetic Advantages are
Obvious Cost Savings Significant
ScrewDirect 150 incl. Snap Transfer Cap
NobelActive ExternalRequires Attachment of one
of these four abutments
12
Attach Remove Long Friction Fit Head to
NobelActive
Straight Friction-fit abutment too long
Heads of Implant exposed above bone
Tried to remove abutment with Forceps
Try in straight abutment.. Too long but locks in
13
Attach Two Short Friction Fit Heads to
NobelActive using Mallet
Jack off abutment using Removal Screw
Shorter Abutment attached to Implants
Shorter Abutment attached to Distal Implant
Tap on Taper Lock Abutments with Mallet
14
Preferred placement is angled between buccal and
lingual platesStraight Post of NobelActive
External requires vertical placement
15
Why Change Drills and Platforms, just to change
threads?
NobelActive
ReActive
RePlus
  • RePlus and ReActive have compatible Tri-Lobe
    Connection
  • Both have Platform switching interface of
    questionable value
  • Both have even taper to allow insertion into an
    undersized socket for bone expansion,
  • Nobel Active has straight outer threads with very
    tapered inside thread dimension
  • RePlus and ReActive have Mini-threads whereas
    NobelActive has horizontal grooves.
  • RePlus and ReActive seal opening at crest of
    ridge whereas NobelActive 4.3 5.0 implants are
    narrower at top, leaving gap
  • RePlus and ReActive have double lead threads on
    body for faster insertion.

16
Very deep threads apically cuts rather than
compresses soft bone - any screw implant will
self-tap in soft bone.
NobelActiveNo Taper to OD of Threads
ScrewPlantGradual Taper for Bone Expansion
  • NobelActive Claim
  • The product is easy to use and provides high
    initial stability and good outcomes.
  • The Apical Threads are too aggressive for
    self-tapping insertion in Dense bone and are
    designed to cut threads in soft bone rather than
    expand and compress the bone for increased
    initial stability. Any Implant will self-tap in
    soft bone.

Deep apical threads will not expand narrow ridge
or compress soft bone
Soft Bone (Balsa) 3.91 in/lbs Insertion
TorqueHard Bone (Oak) 6.35 in/lbs Insertion
Torque
17
ReActive with Tri-Lobe Connection and Platform
Switching
  • Same taper to body as RePlus Implants allow
    insertion in undersized socket for expansion
  • Flat-based deeper threads provide increased
    surface area for greater stability in soft bone
Write a Comment
User Comments (0)