Slide_template_IES.ppt - PowerPoint PPT Presentation

About This Presentation
Title:

Slide_template_IES.ppt

Description:

One Golden instrument at CVS and one at the partial flow system ... PM flow, split ratio. MDLT. Smart Sampler. Smart Sampler. PSS. Partial flow system. 20/40 ... – PowerPoint PPT presentation

Number of Views:49
Avg rating:3.0/5.0
Slides: 17
Provided by: europe54
Learn more at: https://unece.org
Category:

less

Transcript and Presenter's Notes

Title: Slide_template_IES.ppt


1
Particle Measurement Programme Exploratory work
Validation Exercise (JRC) First Validation
Exercise comparisons
B. Giechaskiel, G. Martini, J. Andersson JRC, 30
March 2009
2
Outline
  • Status
  • Exploratory Work (JRC)
  • Preconditioning
  • Particles lt23 nm
  • Validation Exercise (JRC)
  • Partial Full flow systems comparison
  • Number systems comparison
  • After-treatment comparison
  • Validation Exercise comparisons

3
Status
4
Set up
One Golden instrument at CVS and one at the
partial flow system Alternative systems
(EJETEJ3010D, EJTD3790, Nanomet-C) Other
systems (EEPS, 3025A)
TSI( 3025A)
5
Preconditioning
Non-volatile particles gt23 nm Low temperature
modes ? Low emissions High temperature modes ?
High emissions
Non-volatiles gt23 nm 15 min at mode 10 is the
minimum time for Pre-conditioning
6
Pre-conditioning emissions
High emissions of volatiles during passive
regeneration
Non-volatile emissions can be also observed
Non-volatiles
7
Cycles
Low emissions at the rest cycles
High emissions at the beginning of the cycle
Hot WHTC
Cold WHTC
High emissions at high temperature modes
ESC
8
Particles lt23 nm
Total gt3 nm approximately 80 of non-volatiles
gt23 nm
Non-volatiles gt3 nm approximately 40 of
non-volatiles gt23 nm
9
Partial-Full flow systems
Not good PM correlation between partial and full
flow systems (However similar levels)
Very good PN correlation between partial and
full flow systems
10
Number systems comparison
Very good agreement between alternative and
golden systems measuring from CVS in parallel
11
Aftertreatment effect
65 reduction with partial flow Deep Bed
Filter 99 reduction with wall flow filter
EMITECPM Metalit Partial Flow Deep Bed
Filter DPFPt based oxicat upstream of wall flow
filter
12
VE Comparisons - setup
13
VE Comparisons - gaseous
14
VE Comparisons Real time PN
15
VE Comparisons PM and PN
16
Conclusions
  • Exploratory Work (JRC)
  • Preconditioning Regeneration Loading
  • Not high concentration of particles lt23 nm (and
    proportional)
  • Validation Exercise (JRC)
  • Good correlation between partial and full flow
    systems
  • Good correlation between particle number systems
  • Wall flow filters can reduce efficiently number
    emissions
  • Validation Exercise comparisons
  • Background important
  • Quite good repeatability of PN emissions
Write a Comment
User Comments (0)
About PowerShow.com