GRETINA and the Argonne Fragment Mass Analyzer - PowerPoint PPT Presentation

1 / 10
About This Presentation
Title:

GRETINA and the Argonne Fragment Mass Analyzer

Description:

Comparison with GAMMASPHERE and FMA. Stable heavy-ion beams ... Scintillators - betas. Pioneering. Science and. Technology. Office of Science. U.S. Department ... – PowerPoint PPT presentation

Number of Views:36
Avg rating:3.0/5.0
Slides: 11
Provided by: B281109
Category:

less

Transcript and Presenter's Notes

Title: GRETINA and the Argonne Fragment Mass Analyzer


1
GRETINAand the Argonne Fragment Mass Analyzer
  • Dariusz Seweryniak

2
Comparison with GAMMASPHERE and FMA
  • Stable heavy-ion beams up to 10MeV/A
  • Higher Ge rates in GRETINA (?)
  • Higher FMA efficiency
  • Higher yield
  • Better Doppler correction (ER,qR)
  • Polarization measurements
  • FMA focal plane
  • GRETINAGAMASPHERE

3
Physics
  • rp-process nuclei
  • NZ nuclei
  • Proton emitters
  • Trans Uranium nuclei
  • n-rich radioactive beams from CARIBU

4
Argonne Fragment Mass Analyzer
HPGe
GAMMASPHERE
g
PPAC
E
E
Beam
B
Q
Q
Q
Q
M/Q
Recoils
DE-E
W8msr DE/-20 D(M/Q)10 DM/M1/350
Separates beam from heavy reaction
products Disperses according to M/Q independent
of angle and energy
5
FMA efficiency
  • Reaction 58Ni58Ni at 250 MeV
  • En2 MeV, Ep8.7 MeV, Ea16.3 MeV
  • Target-FMA distance 30 cm
  • 3p emission 85, 1a emission 30
  • Requires placing detectors at backward angles
  • Target-FMA with GS 90 cm
  • 1a emission 3

Factor of 10 gain (depends on kinematics)
6
GRETINA rates
40 kHz per crystal is equivalent to GS We can
provide a very selective (infrequent) trigger!
7
Focal plane detection systems
  • PPAC/channel plate - X, Y, TOF, DE
  • Fast detectors (sub ns)
  • Ionization chamber DE, E, Z
  • Pulse shape
  • Large area Si detector E, TOF
  • DSSD ER, TOF, Ep, Ea, Ee, T1/2
  • RDT
  • Currently 480 channels (only 160 with
    digitizers, more?)
  • 20 keV to 200 MeV
  • Fast activities with digitizers
  • Ge detectors isomers, b-delayed g rays, p-g,
    a-g
  • 511-511 suppression
  • Isomer tagging
  • PiN diodes conversion electrons
  • Scintillators - betas

8
Electronics issues
  • External Trigger
  • CP/PPAC 0-2ms after g rays
  • Isomers 0-100ms
  • Fast decays 0-100ms
  • Needs to be combined with g-fold (flexible)
  • Legacy ADC read out
  • CAMAC (FERA bus)
  • VME
  • Digitizers?
  • LBNL
  • XIA
  • Other

9
Mechanical interface
  • Short distance between GRETINA and FMA
  • implies(?) placing detectors at backward angles
  • Focal plane studies and isomer studies require
    close geometry to increase efficiency
  • Several frames?

10
Discussion points
  • GRETINA maximum rates
  • ADC readout
  • Digitizers
  • External Trigger
  • Detector configurations
Write a Comment
User Comments (0)
About PowerShow.com