Cast aluminium block with integrated. stainless steel tubes ( i=36mm, th=3.25mm) Cooling Module ... Aluminium (3-6) and Iron. Phase 1: Preparation & Iron 'floor' ... – PowerPoint PPT presentation

Number of Views:61
Avg rating:3.0/5.0
Slides: 20
Provided by: anspa
Category:
Tags: aluminium | beam | dump

less

Transcript and Presenter's Notes

Title: Beam Dump


1
Beam Dump Cooling
  • Introduction
  • (Location, Access Driving Parameter)
  • Components
  • (Graphite, Iron, Aluminium)
  • Cooling System
  • Layout
  • Installation

2
Location Access
2km
Beam Dump (Hadron Stop)
500m
3
First Design
4
Driving Parameter
5
Graphite Iron
Graphite core
graphite Thermal conductivity160
W/(mK) Tolerances 0.5 mm Good surface quality
6
Cooling System
  • Cast aluminium block with integrated
  • stainless steel tubes (Øi36mm, th3.25mm)

7
Cooling System
8
Cooling System
Primary Heat Exchanger
Easy access, Regular maintenance
9
Cooling System
Connections to TE80 (Heat Exchanger)
  • Lateral connections ? Accessibility
  • 2x6 independent circuits ? Reliability
  • Flexible tubes (metallic) in Beam Dump
  • ? Work in the tunnel minimized
  • ? Absorption of vibrations,
  • thermal dilations
  • Purely metallic connections
  • 2 tubes to TE80

10
Cooling System
Manifold Valves Flow-meters
Operation
  • Monitoring of circuit (TE80)
  • If pressure drop
  • Signal detected (TE80)
  • As soon as access possible
  • Visual inspection of
  • flow indicators in Beam Dump
  • to locate faulty circuit
  • Close circuit
  • Repair
  • (when/if access Beam Dump possible)

2 Tubes to TI8
11
Cooling System
26 Manual Valves, 13 Visual Flow Meters
12 Aluminum Cooling Modules
26 Flexible Tubes
2 Flexible Tubes from Exit Window
2 Tubes to TE80
12
Layout
13
Upstream Wall
Air separation Door ? 1mm stainless steel sheet
14
Downstream Wall
Air separation, Radioprotection Door? 300mm
concrete wall
15
Installation
1875 tons, 500 blocks
Installed between 15/07 - 01/09/2003
16
Installation
  • Installation Sequence

17
Installation
18
Installation
Problem (encountered during phase 4)
19
Installation
Solution
1. Measure topology of iron floor
2. Calculate shim thicknesses to simulate good
slope
(extra time needed 3 days)
20
Installation
Hadron Stop Installation Completed 01/09/2003
Write a Comment