Magnetic coupling to test mass motion - PowerPoint PPT Presentation

1 / 5
About This Presentation
Title:

Magnetic coupling to test mass motion

Description:

Magnetic coupling to test mass motion. Harald L ck. Magnetometer in the East End station ... number of averages: 16. window function: hanning. frequency ... – PowerPoint PPT presentation

Number of Views:138
Avg rating:3.0/5.0
Slides: 6
Provided by: haral2
Category:

less

Transcript and Presenter's Notes

Title: Magnetic coupling to test mass motion


1
Magnetic coupling to test mass motion
  • Harald Lück

2
Magnetometer in the East End station
number of averages 16 window
function hanning frequency
resolution 0.1 Calib. Const.
0.1V/µT
3
(No Transcript)
4
Effect onto mirrors
  • ca. 5 nTrms _at_ 100Hz
  • Assume source _at_ 1m distance ? dB/dx100Hz
    5nTrms/m
  • m 0.25 A m2 / magnet. 3 magnets
  • F m dB/dx 4 nN/mirror100Hz
  • Mirror mass 5.5 kg
  • ?x F/(m f4) (Pendulum res. 1Hz)
  • ?x 7 E -18 m ? h 6E-21 rms100Hz

5
1/f4
Write a Comment
User Comments (0)
About PowerShow.com